Catalog pricing shown. Please Sign In to see your pricing.

TZGE460CL100C

TZGE460CL100C
Package A/C unit, electric cool, gas heat, 14 SEER, R410A, 60,000 cooling BTUH, 100,000 heating input BTUH, 208-230/3/60
Please note an alternative model exists for this Part Number. Please see the Supersedes tab.
Vendor Name:
Thermal Zone
URI Part Number:
TZGE460CL100C
Vendor Part Number:
TZGE448CL100C
Length (In.):
52 7/16
Width (In.):
47 1/2
Height (In.):
41
Shipping Weight (Lbs.):
522
CFM:
2000
Cooling Capacity (BTUH):
59000
Cooling Efficiency (EER):
11.6
Cooling Efficiency (SEER):
14.0
Country of Origin:
US
Heating Capacity (BTUH):
81000
Heating Efficiency DOE (AFUE) Standard:
81.0
Heating Input (BTUH):
100000
MCA (Amps):
32.0
Nominal Tons:
5
Refrigerant:
R410A
Sound Rating Decibels:
79
Voltage:
208-240/3
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov
  • R-410A refrigerant
  • Induced draft combustion
  • Redundant gas valve, with 1 or 2 stages of heating
  • Pre-painted exterior panels and tested to 500 hours salt spray protection
  • Fixed refrigerant metering system
  • Fully insulated cabinet
  • Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic.
  • Access panels with easy grip handles and no-strip screw feature
  • Two-inch disposable return air filters
  • Direct Drive ECM: indoor fan motor is standard with optional belt drive systems
  • Advanced terminal board for simple safety circuit troubleshooting and control box arrangement
  • Field Convertible from vertical to horizontal airflow on all models. No special kit required
  • Provisions for thru-the-bottom power entry capability
  • Single point gas and electric connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots
  • Scroll compressors with internal line-break overload protection
  • Copper tube, aluminum fin coils
  • 24-volt control circuit protected with resettable circuit breaker
  • Low pressure, freeze protection, and high pressure switches


  • Copeland scroll compressors
  • Side/down discharge convertible
  • Accessible blower section/slide out chassis
  • Direct spark ignition/remote flame sensors/induced draft
  • Single point wiring
  • Easily accessible control box
  • Tubular heat exchangers
  • Internal trap on the condensate line eliminates the need for installing an on-site external trap.
  • Thermal expansion valve standard on all models for superior superheat control, reliability, and energy efficiency at all operating conditions.
  • Filter drier standard on all models
  • Molded compressor plugs.
  • A double sloped evaporator coil drain pan assures all water is removed from the unit to improve indoor air quality.
Accessories Replacement Parts Substitutes Supersedes Documents