Catalog pricing shown. Please Sign In to see your pricing.

LDDS6000M6C

LDDS6000M6C
Call To Order
Condensing unit, air cooled, dual semi-hermetic compressor, medium/high temp, beacon, R404A, R507, 60 HP, 208-230/3/60, w/ receiver
Vendor Name:
Larkin
URI Part Number:
LDDS6000M6C
Length (In.):
171
Width (In.):
87.7
Height (In.):
55.6
Shipping Weight (Lbs.):
4320
Application:
Medium Temp, High Temp
Compressor:
4DJ3A300ETSK
Compressor New:
4DJ3R28METSK
Connection Liquid (In.):
1 1/8
Connection Suction (In.):
2 1/8
Connection Type:
ODS
Horsepower:
60
MCA (Amps):
217.8
Oil:
Polyol Ester
Receiver Capacity 90 % Full (Lbs.):
186
Receiver Included:
Yes
Refrigerant:
R404A, R507
Voltage:
208-240/3
Prop65:
WARNING: Cancer and Reproductive Harm- For more information go to www.P65Warnings.ca.gov

Larkin Refrigeration Products is pleased to present the latest in innovative electronic controls-the Beacon®, on our 20 to 80 HP LDDS units. The Beacon is an electric expansion valve controlled by a microprocessor that uses a flashing signal to indicate system performance, including superheat. The Beacon replaces the TXV, solenoid valve, time clock, head pressure control valve, and defrost termination controls. By continuous monitoring of system performance, the head pressure on a Beacon system can be lowered in cooler ambients resulting in energy savings comparable to the mechanical pressure control system. The Beacon Components come factory installed and wired for quicker installations. Temperature sensors have been placed in optimum locations for stable performance. We have also preset the system defaults to work with most standard installations. Superheat is preset at 8°F. All the contractor has to do is run the tubing and 24 volt (low voltage) thermostat wire. Settings are easily changed on the board via dipswitches. With its unique design, the Beacon will also assist the service technician in diagnosing a problem (e.g., faulty sensor or pressure switch cutout). In addition to the Beacon control system, we also offer the Smart Controller, that can direct the operation of the Beacon board up to 1500' from the unit. This controller will adjust superheat settings, defrost periods and room temperatures. Also, the Smart Controller can be locked to prevent unauthorized tampering of settings. Recently, Larkin announced the use of the Smart Defrost feature that monitors the frosting of the coil and will only defrost the coil when there is a frost load. The advantages of all three of these systems will be obvious to the service contractor that has to climb onto racks in cold warehouses in order to set controls or diagnose performance.



  • Dual compressor, dual circuit units
  • Receiver capacity and connection sizes are per circuit
Documents