Catalog pricing shown. Please Sign In to see your pricing.

JDDS6000L6C

JDDS6000L6C
Call To Order
Condensing unit, air cooled, dual semi-hermetic compressor, low temp, beacon, R22, R404A, R507, 60 HP, 208-230/3/60, w/ receiver
Vendor Name:
Bohn
URI Part Number:
JDDS6000L6C
Length (In.):
171
Width (In.):
87.7
Height (In.):
55.6
Shipping Weight (Lbs.):
4340
Application:
Low Temp
Compressor:
6DT3A300ETSK
Compressor New:
6DT3F11METSK
Connection Liquid (In.):
1 1/8
Connection Suction (In.):
2 1/8
Connection Type:
ODS
Horsepower:
60
MCA (Amps):
221
Oil:
Polyol Ester
Receiver Capacity 90 % Full (Lbs.):
123
Receiver Included:
Yes
Refrigerant:
R404A, R507A, R407A, R407C, R407F, R448A, R449A
Voltage:
208-240/3

Bohn Refrigeration Products is pleased to present the latest in innovative electronic controls—the Beacon®, on our JDDS units. The Beacon is an electric expansion valve controlled by a microprocessor that uses a flashing signal to indicate system performance, including superheat. The Beacon replaces the TXV, solenoid valve, time clock, head pressure control valve, and defrost termination controls. By continuous monitoring of system performance, the head pressure on a Beacon system can be lowered in cooler ambients resulting in energy savings comparable to the Bohnmizer™ system. The Beacon Components come factory installed and wired for quicker installations. Temperature sensors have been placed in optimum locations for stable performance. We have also preset the system defaults to work with most standard installations. Superheat is preset at 8°F. All the contractor has to do is run the tubing and 24 volt (low voltage) thermostat wire. Settings are easily changed on the board via dipswitches. With its unique design, the Beacon will also assist the service technician in diagnosing a problem (e.g., faulty sensor or pressure switch cutout). In addition to the Beacon control system, we also offer the Smart Controller™ that can direct the operation of the Beacon board up to 1500' from the unit. This controller will adjust superheat settings, defrost periods and room temperatures. Also, the Smart Controller can be locked to prevent unauthorized tampering of settings. Recently, Bohn announced the use of the Smart Defrost™ feature that monitors the frosting of the coil and will only defrost the coil when there is a frost load. The advantages of all three of these systems will be obvious to the service contractor that has to climb onto racks in cold warehouses in order to set controls or diagnose performance.



  • Dual compressor, dual circuit units
  • Receiver capacity and connection sizes are per circuit
  • Receiver capacity for R404A. For R22 multiply by 1.14