Catalog pricing shown. Please Sign In to see your pricing.

S8610U3009

S8610U3009
Intermittent pilot ignition module, 24 Volt, universal, 15 to 90 sec lockout time
Vendor Name:
Resideo
URI Part Number:
S8610U3009
Vendor Part Number:
S8610U3009
Length (In.):
5.44
Width (In.):
2.64
Height (In.):
3.93
Shipping Weight (Lbs.):
0.8
Country of Origin:
Mexico
Includes:
Spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable
Supply Voltage:
24V
Use with:
Q345, Q348, Q362, Q373, Q381, Q179C, Q354, Q345, Q348, Q362, Q373, Q381
Shipping Height (In.):
1
Shipping Width (In.):
1
Prop65:
No

Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) intermittent pilot ignition modules. Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers and other heating appliances.

  • Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances
  • Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed.
  • For use with natural or LP gas
  • Includes remote reset, automatic vent damper plug
  • For use in single rod or dual rod/remote sense applications
  • Supply voltage: 24V
Substitutes Documents

Related Products