Catalog pricing shown. Please Sign In to see your pricing.

C610U1C

C610U1C
Intermittent pilot ignition module, 24 Volt, universal, 0.15 micro A minimum flange current, 2 amps
Vendor Name:
Baso
URI Part Number:
C610U1C
Vendor Part Number:
C610U1C
Shipping Weight (Lbs.):
1
Contact Rating (Amps):
2
Minimum Flange Current (MicroAmps):
0.15
Voltage:
24 Vac/ 50/60 Hz

The BG1600M51E1AA is a microprocessor based ignition control. The microprocessor provides reliable software control of all timings and operates a diagnostic LED. It provides ignition sequence, flame monitoring, and safety shutoff for intermittent pilot boilers, furnaces and other heating appliances.
BASO has designed-in features to retrofit other universal direct spark ignition controls with spark ignition and flame rectification such as: Johnson Controls, Honeywell, White Rodgers, Fenwal, and Robertshaw.
It replaces controls with the following specifications:

  • Flame detection using flame rectification technology
  • Single rod (local sense) or dual rod (remote sense) flame sensing
  • 100% shutoff/lockout with 5 minute continuous retry
  • Trial times of 25 seconds or longer
  • Prepurge period 1 second or less
  • Main burner 400,000 BTU/hr maximum
  • Pilot burners with flow rates of 1,500 Btu/hr or less
  • With or without automatic vent damper
  • Must be used with redundant gas valves and not subjected to temperatures below -40°F or above 170°F
    Direct replacement to Johnson Controls G779LHA.
Substitutes

Related Products