RAWL150DAZ

RAWL150DAZ
Condensing unit, air conditioning, R410A, 12.5 tons, 460/3/60
Vendor Name:
Thermal Zone
URI Part Number:
RAWL150DAZ
Vendor Part Number:
RAWL150DAZ
Length (In.):
72 3/8
Width (In.):
38 3/8
Height (In.):
44 3/4
Shipping Weight (Lbs.):
690.00
CFM:
8000
Connection Liquid (In.):
5/8
Cooling Capacity (BTUH):
146000
Cooling Efficiency (EER):
11.1
Maximum Fuse / Breaker Size (Amps):
35
MCA (Amps):
27
Nominal Tons:
12.5
Nominal Tons_Sort:
12.5
Rating Selection:
RHGL-180Z
Refrigerant:
R410A
Voltage:
460/3
  • Cabinet: galvanized steel with a durable finish. Stamped louvered panels offer 100% protection for the condenser coil.
  • Compressor: hermetically sealed with internal overload protection and durable insulation on motor windings. The entire compressor is mounted on rubber grommets to reduce vibration and noise.
  • Condenser coil: constructed with copper tubes and aluminum fins mechanically bonded to the tubes for maximum heat transfer capabilities.
  • Base pan: galvanized steel.
  • Refrigerant connections: field piping connections are made through a fixed panel. This allows removal of access panels after piping connections have been made.
  • Crankcase heaters: standard, all models. Prevents refrigerant migration to compressor(s).
  • Low ambient control: a pressure sensitive fan cycling control to allow unit operation down to 0°F is standard.
  • Service valves: standard on liquid and suction lines. Allows outdoor section to be isolated from indoor coil.
  • Service access: control box as well as the compressor and other refrigerant controls are accessible through access panels. Control box may be open without affecting the normal operation of the unit. Condenser fan motors are accessible by removing wire grilles.
  • Filter drier: standard (uninstalled) on all models. Helps ensure refrigerant cleanliness.
  • Transformer: step-down type, line to 24 volts. Provides control circuit voltage.
  • Contactor: electrical switch which operates the compressor and condenser fans.
  • High pressure control:opens the contactor circuit on high refrigerant pressure; manual reset.
  • Low pressure control: stops compressor operation in the event of loss of refrigerant.
  • Condenser motor (Direct Drive): ball bearing 1075 RPM motors are mounted to minimize vibration and noise problems. These are permanent split capacitor types. ECM fan motor (10 Ton)
  • Testing: all units are run tested at the factory prior to shipment. Units are shipped with a holding charge of nitrogen.
  • External gauge ports: allows pressures to be checked without removing access panel.
  • Coil louvers: helps prevent damage to outdoor coils.
  • Time delay: supplied on tandem compressor models to provide a delay between stages.